手持焊接軟件說明:版本411(中英)

本文闡述版本號為411的軟件說明,您可以通過監測頁面查看系統版本后三位

新增:診斷功能、監測界面重構

This article describes the software description with version 411. You can view the last three parts of the system version through the monitoring page


Added: diagnostic function, monitoring interface reconstruction



①此界面可以看到當前工藝參數(此頁面不可修改工藝)及即時報警信息。


②開機狀態時使能默認為ON,指示紅光默認為LINE,焊接模式為連續

   關閉使能時,將不會給激光器發送使能信號,可用來試出氣功能

   關閉紅光指示,將不會給電機供電,此時紅光為一個點,用于調整中心

   焊接模式分為連續和點焊,當選擇點焊時,需要在設置頁面設置點焊類型


③安全地鎖分為灰色和綠色,當安全地鎖有效時,顯示為綠色,此時扣動扳機后出光

① This interface can see the current process parameters (this page cannot modify the process) and instant alarm information.




② Enable the default is ON in the startup state, indicating the red light is LINE by default, and the welding mode is continuous


When the enable function is turned off, no enable signal is sent to the laser, which can be used to test the gas function


Turning off the red light indicator will not power the motor, and the red light is a point for adjusting the center


The welding mode is divided into continuous and spot welding. When selecting spot welding, you need to set the spot welding type on the Settings page




③ The safety lock is divided into gray and green, when the safety lock is effective, it is displayed as green, and the light comes out after pulling the trigger



①工藝界面包含調試的工藝參數,點擊框(紅色)可修改,修改完畢后點擊OK,然后保存在快捷工藝,使用時點擊導入即可 (修改-保存-導入)。


②掃描速度范圍2-6000mm/S,掃描寬度范圍0^6mm。掃描速度受到掃描寬度的限制,該限制關系是:10≤掃描速度/(掃描寬度*2) ≤1000如果超過限制,則會自動變為極限值。掃描寬度設為0時,則不會掃描(即點光源)

(最常用的掃描速度:300mm/S,寬度2.5-4mm)。


③峰值功率需小于等于參數頁激光器功率(如激光器功率1000W,則此數值不高于1000)。


④占空比范圍0~100(默認100,通常情況下不需要改動)。


⑤脈沖頻率范圍建議5-5000Hz(默認2000,通常情況下不需要改動)。


⑥點擊右上方的HELP按鈕可以獲取更多相關參數解釋。


⑦修改參數后,可在首頁查看是否導入成功


⑧參考工藝,可在小程序的工藝里參考

① Process interface contains debugging process parameters, click the box (red) to modify, click OK after modification, and then save in the shortcut process, click import when using (modify - save - import).




② Scanning speed range 2-6000mm/S, scanning width range 0^6mm. The scanning speed is limited by the scanning width, the limiting relationship is :10≤ scanning speed /(scanning width *2) ≤1000 If the limit is exceeded, it will automatically become the limit value. When the scan width is set to 0, no scanning will be done (i.e., point light source)


(The most commonly used scanning speed: 300mm/S, width 2.5-4mm).




③ The peak power should be less than or equal to the laser power of the parameter page (such as the laser power 1000W, the value is not higher than 1000).




④ Duty cycle range: 0 to 100 (Default: 100, usually do not need to change).




⑤ The pulse frequency range is recommended to be 5-5000Hz (the default is 2000, usually do not need to change).




⑥ Click the HELP button on the upper right to obtain more related parameters.




⑦ After modifying the parameters, you can check whether the import is successful on the home page




⑧ Reference process, can be referred to in the process of small program



密碼123456,每次設置后需要點擊保存


激光器功率為使用的激光器的功率,請正確填寫。


②開關氣延時默認200ms,范圍200ms-3000ms。


③開光時由工藝功率的百分之N1,漸進至100%;關光時由工藝功率的百分之100%, 漸進至N2;(如下圖所示)。

Password 123456, you need to click save after each setting




① Laser power indicates the power of the used laser. Enter the correct value.




② The switching gas delay is 200ms by default and ranges from 200ms-3000ms.




③ When opening light, from 1% of the process power, gradually to 100%; Turn off the light from 100% of the process power, gradually to N2; (as shown in the picture below).



設置界面解釋.png

一般預設開關光功率20%,開關光漸進時間200ms


④送絲延時補償即相對于出光信號的送絲提前時間,可配合回抽功能使用,默認不設置


⑤溫度報警閥值最大65℃,該值設為0時,不檢測溫度報警。


⑥掃描校正系數范圍0.01~4,系數目標線寬/測量線寬:一般為1.25。


⑦激光中心偏移-3~3mm,減小往左移,增大往右移,應用于調整紅光中心


⑧氣壓/水冷機/激光器報警電平信號默認為低電平,當使用此報警信號時,如加裝了外部氣壓報警器則改成高電平有效,否則會出現異常的報警,其他報警信號同理。


⑨點焊持續時間為當扣動扳機后的出光時間,即使松開按鈕,依然會按照出花時間來出光(點焊功能)

⑩點焊間隔時間為扣動扳機按鈕后,兩次點焊之間的停光時間(點焊功能)


⑧點擊右上方的HELP按鈕可以獲取更多相關參數解釋。

Generally, the preset switching optical power is 20%, and the switching optical progressive time is 200ms




④ Wire feed delay compensation is relative to the wire feed advance time of the optical signal, which can be used with the pullback function, and is not set by default




⑤ The maximum temperature alarm threshold is 65℃. When the value is set to 0, the temperature alarm is not detected.




The scan correction coefficient ranges from 0.01 to 4, and the coefficient target line width/measurement line width is generally 1.25.




⑦ Laser center offset -3~3mm, reduce to the left, increase to the right, used to adjust the red light center




Air/water cooler/laser alarm level signal default is low, when using this alarm signal, such as the installation of an external air pressure alarm is changed to a high level effective, otherwise there will be abnormal alarm, other alarm signals the same.




⑨ Spot welding duration is the light time after pulling the trigger, even if the button is released, the light will still be produced according to the time spent (spot welding function)


⑩ Spot welding interval time is the stop light time between two spot welding after pulling the trigger button (spot welding function)




⑧ Click the HELP button on the upper right for more parameter explanation.





此頁面顯示了各信號的狀態及設備信息,請注意,只有在設置界面為中文的情況下,此監測界面才有顯示,否則為其他老版本的監測


①輸入信號狀態

激光器扳機信號:當扣動扳機后,此狀態由灰色變綠色生效

安全地鎖信號:當槍頭和安全地鎖接觸時,此狀態由灰色變綠色生效

激光器/水冷機/氣壓報警信號:監測其設置的高低電平

This page displays the status and device information of each signal. Please note that this monitoring interface is displayed only when the setting interface is in Chinese, otherwise it is for other old versions of monitoring




① Input signal status


Laser trigger signal: When the trigger is pulled, this state changes from gray to green


Safety lock signal: This status changes from gray to green when the gun head and safety lock are in contact


Laser/water cooler/air pressure alarm signal: Monitor its set high and low levels




②輸出信號狀態

當信號輸出時,此區域的信號出現改變,可直視化

② Output signal status


When the signal is output, the signal in this area changes and can be directly viewed




③設備基本信息

設備授權:可對設備進行使用時長授權,當設備使用超過其設定的時間,則顯示授權終止,

系統版本:三組數字,第一組為硬件版本,第二組為單片機的程序版本,第三組為觸摸屏版本

③ Basic device information


Device authorization: The device can be authorized for the duration of use. When the device is used for more than its set time, the authorization is displayed as terminated.


System version: three groups of numbers, the first group is the hardware version, the second group is the program version of the single chip microcomputer, and the third group is the touch screen version




④電源狀態

顯示了設備此時的輸入電壓電流

④ Power status


Displays the input voltage and current of the device at this time




⑤通訊狀態

顯示了觸摸屏和主板的通訊,如出現未同步,則檢查連接線

⑤ Communication status


The communication between the touch screen and the motherboard is displayed. If there is no synchronization, check the connection cable



⑥診斷

此界面點擊診斷進入診斷界面,用于測量各信號口是否有實際的輸出,通常輸出值和檢測值一致,當不一致時,負載異常,如當激光器不出光時,通過開關單個的端口通過激光器的監測軟件或萬用表測量,可真實的反饋信號是否發出去

⑥ Diagnosis


Usually, the output value is consistent with the detected value. When the output value is inconsistent, the load is abnormal. For example, when the laser does not emit light, the monitoring software or multimeter of the laser can be used to measure whether the real feedback signal is sent