焊接頭問題處理:電機不擺動(中英)



正常光斑通過擺動電機變成一條光斑線(左),如果當電機不擺動了,那么就會顯示一個點出來(右)

The normal spot becomes a spot line (left) by swinging the motor, and if the motor does not swing, then a dot will be displayed (right)


原因分析:

一.軟件部分是否設置正確

設置-掃描矯正:1.25

工藝-掃描寬度:焊接系統3-5,清洗系統20-150

首頁-指示紅光:開啟

Cause analysis:

One. Whether the software section is set up correctly

Setup - Scan Correction: 1.25

Process-scanning width: welding system 3-5, cleaning system 20-150

Home - Indicator Red Light: On


二.硬件部分檢查

1.擺動電機的供電為15V電源供電,我們應首先測量15V開關電源的供電是否正常。

Two. Hardware section check

1. The power supply of the swing motor is powered by 15V power supply, we should first measure whether the power supply of 15V switching power supply is normal.


2.另外,15V開關電源分正負,錯誤的接線也會致使電機不工作,V1接15V+,V2接15V-,15V開關電源上的任意COM接2號腳GND!

2. In addition, the 15V switching power supply is divided into positive and negative, the wrong wiring will also cause the motor to not work, V1 is connected to 15V+, V2 is connected to 15V-, and any COM on the 15V switching power supply is connected to GND on pin 2!



3.(型號SUP20S/T/C)檢查一下兩頭的接口是否插到位和驅動板上有沒有插錯

3. (Model SUP20S/T/C) Check whether the interfaces at both ends are plugged into place and whether there is any misinsertion on the driver board





4.(型號SUP15S)如果電源正常,那一般都是斷路導致,控制盒和電機通過一根2芯線供電,重點檢查2芯線的航插,拆開看是否斷路

4. (Model SUP15S) If the power supply is normal, it is generally caused by an open circuit, the control box and the motor are powered by a 2-core wire, focus on checking the 2-core wire's air plug, disassemble to see if the circuit is open


5.(型號SUP15S)當2芯線沒有問題的時候,檢查5芯線的信號航插,也是拆開看是否有斷路

5. (Model SUP15S) When there is no problem with the 2-core wire, check the signal of the 5-core wire, and also disassemble it to see if there is an open circuit


6.檢查主板與驅動的彩虹鏈接線是否松動

6. Check whether the rainbow link between the motherboard and the driver is loose


7.當以上都無法處理是,更換一根電機線,技術群內溝通即可

7. When the above can not be handled, replace a motor line, technical group communication can be